This document is a user manual for TPK AS-5630A ionizing air blower (PC type), which introduces the working principle, features, specifications, safety instructions, installation methods, pre-use inspection items, operation procedures, maintenance methods, troubleshooting, and optional accessories of the product.


TPK AS-5630A Ionizing Air Blower User Manual - cover page
Brand
TPK
Document type
User Manual
Language
Chinese
Pages
8
File format
PDF
File size
255 KB
Published
16 December, 2011
Updated
28 September, 2023
MD5 checksum
038F2B0961DCE3C80714989AF1440EC9

About this manual

The TPK AS-5630A ionizing air blower is a PC‑type automatic alarm ionizer designed to neutralize static electricity on sensitive electronic components in testing, assembly, and laboratory environments. It generates a flow of positive and negative ions to neutralize charged objects and includes adjustable fan speed, ion balance control, and a heating function.

The manual covers the device’s features, technical specifications, safety guidelines, installation steps, pre‑use inspection, operating procedures, routine maintenance, fault troubleshooting, and optional accessories, providing clear guidance for safe and effective use. This manual is written in Chinese.

What's inside

  • Overview
  • Features
  • Specifications
  • Safety
  • Installation
  • Pre‑use Inspection
  • Operation
  • Maintenance
  • Troubleshooting
  • Optional Parts

Specifications

Fan airflow high speed2.4 m³/min
Airflow speed low30 cm/s
Ozone generation< 0.01 PPM
Noise low speed40 dB
Noise high speed45 dB
Ion balance tolerance± 50 V
Weight2.8 kg
Dimensions14.0 cm × 22.0 cm × 8.4 cm
Operating temperature range0 °C – 50 °C

Frequently asked questions

How do I clean the ion emitter?

Rotate the cleaning knob clockwise to the end, then release; this cleans the ion emitter needle.

What should I do if the unit sounds an alarm?

Check for dust on the ion emission needle and clean it, then adjust the ion balance if needed.

What are the recommended ambient humidity conditions for operation?

Use the device in an environment with 50 % – 70 % relative humidity.

How often should the ion emitter be cleaned?

It is recommended to clean the ion emitter once a week.