This document is a user manual for TPK AS-5630A ionizing air blower (PC type), which introduces the working principle, features, specifications, safety instructions, installation methods, pre-use inspection items, operation procedures, maintenance methods, troubleshooting, and optional accessories of the product.
The TPK AS-5630A ionizing air blower is a PC‑type automatic alarm ionizer designed to neutralize static electricity on sensitive electronic components in testing, assembly, and laboratory environments. It generates a flow of positive and negative ions to neutralize charged objects and includes adjustable fan speed, ion balance control, and a heating function.
The manual covers the device’s features, technical specifications, safety guidelines, installation steps, pre‑use inspection, operating procedures, routine maintenance, fault troubleshooting, and optional accessories, providing clear guidance for safe and effective use. This manual is written in Chinese.
| Fan airflow high speed | 2.4 m³/min |
|---|---|
| Airflow speed low | 30 cm/s |
| Ozone generation | < 0.01 PPM |
| Noise low speed | 40 dB |
| Noise high speed | 45 dB |
| Ion balance tolerance | ± 50 V |
| Weight | 2.8 kg |
| Dimensions | 14.0 cm × 22.0 cm × 8.4 cm |
| Operating temperature range | 0 °C – 50 °C |
Rotate the cleaning knob clockwise to the end, then release; this cleans the ion emitter needle.
Check for dust on the ion emission needle and clean it, then adjust the ion balance if needed.
Use the device in an environment with 50 % – 70 % relative humidity.
It is recommended to clean the ion emitter once a week.