Astec LPS250 Series 250W Power Supply Datasheet


Astec LPS250 Series 250W Power Supply Datasheet - cover page
Brand
ASTEC
Category
AC-DC Switching Power Supply
Document type
Datasheet
Language
English
Pages
2
File format
PDF
Published
04 December, 2011
Updated
29 September, 2023
MD5 checksum
37A626AB677E92A65F7523D25F40B168

About this manual

The Astec LPS250 Series provides 250 watts of single-output power with active power factor correction and IEC EN61000-3-2 compliance. It features remote sense, remote inhibit, power fail, DC power good, and single-wire current sharing, with optional top fan (-CF) or end fan (-CEF) covers.

The series operates from 85-264 VAC (120-300 VDC) input, with 75% typical efficiency and 0.99 power factor. Output voltages include 5V, 12V, 15V, and 24V models, each with 2:1 adjustment range. Supervisory outputs provide 5V@100mA and 12V@500mA. The units meet FCC/CISPR/EN55022 Class B EMI standards and carry VDE, UL, CSA, and NEMKO safety approvals.

What's inside

  • Special Features
  • Environmental
  • Electrical Specs
  • Input
  • Output
  • Logic Control
  • Safety Approvals
  • Ordering Information
  • Pin Assignments
  • Mating Connectors

Specifications

Total Power250 Watts
Input Voltage Range85-264 VAC / 120-300 VDC
Number of OutputsSingle
Operating Temperature0°C to 50°C ambient
Storage Temperature-40°C to 85°C
MTBF>550,000 hours at full load, 25°C
Efficiency75% typical at full load
Power Factor0.99 typical
Switching Frequency120 kHz
Overvoltage Protection (5V)5.7 to 6.7 VDC
Overload Protection110-145% above peak rating
Remote Sense Compensation0.5 V lead drop minimum
Hold-up Time20 ms at 250W load, 115 VAC
Supervisory Outputs5V@100mA, 12V@500mA
Weight2.6 lb / 1.19 kg
Safety ApprovalsVDE 0805/EN60950, UL1950, CSA 22.2-234, NEMKO EN60950
EMI ComplianceFCC/CISPR/EN55022 Class B

Frequently asked questions

What is the input voltage range for the LPS250 series?

The LPS250 series accepts 85-264 VAC or 120-300 VDC input.

What is the operating temperature range?

Operating temperature is 0°C to 50°C ambient, with derating to 70°C.

What safety approvals does the LPS250 series have?

It carries VDE 0805/EN60950, UL1950, CSA 22.2-234, and NEMKO EN60950 approvals.

What is the hold-up time at full load?

Hold-up time is 20 ms at 250W load with 115 VAC nominal line.

Download PDF

More ASTEC Manuals


View all ASTEC manuals →