The DVP01PU-H2 is an open‑type pulse generation unit used for speed or position control of step and servo drive systems, capable of outputting pulses up to 200 kPPS. It features 54 built‑in 16‑bit control registers and supports up to eight extension modules without occupying I/O points.

This manual covers safety warnings, installation in a dust‑ and humidity‑protected enclosure, wiring guidelines, LED indicator functions, I/O terminal specifications, communication settings, and detailed parameter registers. It also includes environmental specifications, error codes, and troubleshooting procedures.

What's inside

  • Warning
  • Introduction
  • Product Profile
  • LED Indicators
  • I/O Terminal Signals
  • Wiring
  • Specifications
  • Communication Settings
  • Error Code & Troubleshooting
  • Control Registers

Specifications

Power supply voltage24V DC (-15% ~ +20%)
Current consumption140 ± 30 mA
Maximum output pulse frequency200 kPPS
Number of control registers54 16‑bit registers
Maximum connected modules/axes8
Operating temperature range0 °C ~ 55 °C
Storage temperature range-25 °C ~ 70 °C
RS‑485 communication baud rates4,800 / 9,600 / 19,200 / 38,400 / 57,600 / 115,200 bps

Frequently asked questions

What is the maximum output pulse frequency of the DVP01PU-H2?

The unit can output pulses up to 200 kPPS.

How many extension modules can be connected to the DVP01PU-H2?

Up to eight modules or axes can be connected without using any I/O points.

What are the power supply requirements for the DVP01PU-H2?

It requires a 24 V DC supply with a tolerance of –15 % to +20 % and draws about 140 ± 30 mA.

What wiring precautions should be taken before powering the unit?

Switch off power before wiring, do not touch terminals while power is on, keep power wiring separate from I/O wiring, and use 60/75 °C copper conductors.