About this manual

Delta EME-A22A is an analog extension card for VFD-E series AC motor drives. This instruction sheet tells users to read it thoroughly before installing option cards and putting them into use, and notes that the content may be revised without prior notice.

The document covers layout, installation, environmental and input/output specifications, voltage/current switch details, and wiring notes. It includes requirements for powering off the AC motor drive before installation, screw and terminal torque values, wire gauge, and precautions for avoiding interference.

What's inside

  • Layout
  • Installation
  • Specification
  • Environmental
  • Inputs/Outputs
  • Voltage/Current Switch
  • Notes

Specifications

Input voltage0–10 VDC
Input impedance100 kΩ
Resolution12 bits
Output voltage0–10 VDC
Output current0–20 mA
Operating temperature-10°C to 50°C (non-condensing and not frozen)
Mounting screw torqueMaximum 2 kgf-cm

Frequently asked questions

What is the Delta EME-A22A?

It is an analog extension card for the VFD-E series AC motor drive.

What should be confirmed before installing the card?

Make sure the AC motor drive is powered off before operation.

How are parameters set when the extension card is installed?

When correctly installed, the card is automatically detected and parameters can be set in Group 12.

What distance should extension card wires keep from other wiring?

Route them separately and at least 15 cm away from other control, motor and power wires.