CPF01 indicates a COM-ERR(OP&INV) with operator transmission error 2, transmission error occurring more than 2 seconds after communication with the operator started, or poor contact of the digital operator terminals. The manual's first action is: “Remove the digital operator and reinstall it”
- Model
- Yaskawa VARISPEED-616G5
- Display shows
- COM-ERR(OP&INV) (CPF01)
- Type
- Error code
- Source
- Manual p. 276
What CPF01 means
COM-ERR(OP&INV) p. 276
Common causes
- Operator transmission error 2 p. 276
- Transmission error occurred more than 2 seconds after communication with the operator started p. 276
- Poor contact of the digital operator terminals p. 276
- Faulty inverter control circuit p. 276
What to do
Before you service the product, read the safety instructions in the manual p. 4.
If CPF01 is still not resolved
This page summarises what the manufacturer’s manual says about CPF01; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.