CPF00 indicates a COM-ERR(OP&INV) with operator transmission error 1, inability to communicate with the operator within 5 seconds after power-on, or poor contact of the digital operator terminals. The manual's first action is: “Remove the digital operator and reinstall it”
- Model
- Yaskawa VARISPEED-616G5
- Display shows
- COM-ERR(OP&INV) (CPF00)
- Type
- Fault code
- Source
- Manual p. 276
What CPF00 means
COM-ERR(OP&INV) p. 276
Common causes
- Operator transmission error 1 p. 276
- Unable to communicate with the operator within 5 seconds after power‑on p. 276
- Poor contact of the digital operator terminals p. 276
- Faulty inverter control circuit p. 276
- Communication fault of the digital operator; abnormal connection between the digital operator and the inverter p. 276
What to do
- Remove the digital operator and reinstall it p. 276
- Swap the inverter p. 276
- Remove the operator and reinstall it to try p. 276
Before you service the product, read the safety instructions in the manual p. 4.
If CPF00 is still not resolved
This page summarises what the manufacturer’s manual says about CPF00; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.