Fault codeA. EA2
This code indicates a servo unit DRV fault 2 occurred during MECHATROLINK-II communication when user parameters were edited using a digital operator or computer. The manual's first action is: “Zero‑speed stop”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- DRV Alarm 2 (A. EA2)
- Type
- Fault code
- Source
- Manual p. 291
What A. EA2 means
DRV Alarm 2 p. 291
Common causes
- Servo unit DRV fault 2 occurred p. 291
- Occurs during MECHATROLINK‑II communication p. 291
- During MECHATROLINK‑II communication, user parameters were edited using a digital operator or computer. p. 291
- MECHATROLINK‑II transmission cycle change p. 291
What to do
- Zero‑speed stop p. 291
- Servo unit fault – replace servo unit p. 291
- During MECHATROLINK‑II communication, do not edit user parameters with the digital operator; do not connect a computer p. 291
- Remove the cause of the command controller’s transmission cycle change p. 291
Before you service the product, read the safety instructions in the manual p. 292.
If A. EA2 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A. EA2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.