Alarm codeA CC0
Rotation Count Upper‑limit Mismatch means the encoder and servo unit have inconsistent rotation count upper‑limit values. The manual's first action is: “DB stop”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- Rotation Count Upper‑limit Mismatch (A CC0)
- Type
- Alarm code
- Source
- Manual p. 290
What A CC0 means
Rotation Count Upper‑limit Mismatch p. 290
Common causes
- Encoder and servo unit have inconsistent rotation count upper‑limit values p. 290
- Occurred when the control power was turned on p. 290
- Encoder rotation count upper‑limit not set or has been changed p. 290
- Servo unit circuit board fault p. 290
What to do
- DB stop p. 290
- Correctly set parameter Pn205 (range 0–65535) p. 290
- When the alarm occurs, execute setting change Pn013 p. 290
- Replace the servo unit p. 290
Before you service the product, read the safety instructions in the manual p. 292.
If A CC0 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A CC0; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.