YASKAWA III series SGM/SGDS Error A CC0: Rotation Count Upper‑limit Mismatch

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Alarm codeA CC0

Rotation Count Upper‑limit Mismatch means the encoder and servo unit have inconsistent rotation count upper‑limit values. The manual's first action is: “DB stop”

Model
YASKAWA III series SGM/SGDS
Display shows
Rotation Count Upper‑limit Mismatch (A CC0)
Type
Alarm code
Source
Manual p. 290

What A CC0 means

Rotation Count Upper‑limit Mismatch p. 290

Common causes

  • Encoder and servo unit have inconsistent rotation count upper‑limit values p. 290
  • Occurred when the control power was turned on p. 290
  • Encoder rotation count upper‑limit not set or has been changed p. 290
  • Servo unit circuit board fault p. 290

What to do

  1. DB stop p. 290
  2. Correctly set parameter Pn205 (range 0–65535) p. 290
  3. When the alarm occurs, execute setting change Pn013 p. 290
  4. Replace the servo unit p. 290

Before you service the product, read the safety instructions in the manual p. 292.

If A CC0 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A CC0; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.