YASKAWA III series SGM/SGDS Error A C92: Encoder Communication Timer Fault

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Fault codeA C92

Encoder Communication Timer Fault means the communication timer between the encoder and servo unit is abnormal. The manual's first action is: “DB stop”

Model
YASKAWA III series SGM/SGDS
Display shows
Encoder Communication Timer Fault (A C92)
Type
Fault code
Source
Manual p. 290

What A C92 means

Encoder Communication Timer Fault p. 290

Common causes

  • Communication timer between encoder and servo unit is abnormal p. 290
  • Occurred when the control power was turned on or during operation p. 290
  • Encoder cable too long, causing interference p. 290
  • Encoder cable abrasion or sheath damage, signal line interfered p. 290
  • Encoder cable bundled with high‑current lines or placed too close p. 290
  • FG potential varies due to motor‑side equipment (e.g., welding machine) p. 290
  • Encoder signal line is interfered p. 290
  • Encoder subjected to excessive vibration/shock p. 290
  • Encoder fault p. 290
  • Servo unit circuit board fault p. 290

What to do

  1. DB stop p. 290
  2. Replace cable with multi‑strand twisted or shielded cable, conductor ≥0.12 mm², tinned soft copper p. 290
  3. Maximum cable length 20 m p. 290
  4. Correct encoder cable routing p. 290
  5. Route encoder cable away from surge voltage locations p. 290
  6. Connect equipment ground to prevent leakage to FG side p. 290
  7. Implement EMI mitigation for encoder wiring p. 290
  8. Reduce machine vibration or install the servo motor correctly p. 290
  9. Replace the servo motor p. 290
  10. Replace the servo unit p. 290

Before you service the product, read the safety instructions in the manual p. 292.

If A C92 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A C92; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.