YASKAWA III series SGM/SGDS Error A.020: User parameter checksum error 1

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Error codeA.020

Abnormal data in internal parameters of the servo unit. The manual's first action is: “DB stop.”

Model
YASKAWA III series SGM/SGDS
Display shows
User parameter checksum error 1 (A.020)
Type
Error code
Source
Manual p. 289

What A.020 means

User parameter checksum error 1 p. 289

Common causes

  • Abnormal data in internal parameters of the servo unit. p. 289
  • Occurs when the control power is turned on. p. 289

What to do

  1. DB stop. p. 289
  2. If the control power drops to about AC 30–60 V, restore the power to normal and perform user‑parameter initialization (Fn005). p. 289

Before you service the product, read the safety instructions in the manual p. 292.

If A.020 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A.020; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.