MOTOWELD MEMORY ERROR4 indicates welding parameters were not saved properly during power failure or interruption, and must be reset after saving changes. The manual's first action is: “The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD "4.2.10 System Reset"). If the error occurs again, the board may be broken. Contact your Yaskawa representative.”
- Model
- Yaskawa 2DX200
- Display shows
- MOTOWELD MEMORY ERROR4 (4265)
- Type
- Error code
- Source
- Manual p. 61
What 4265 means
MOTOWELD MEMORY ERROR4 p. 61
Common causes
- Sub Code: MOTOWELD's Err Code. p. 61
What to do
- The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD "4.2.10 System Reset"). If the error occurs again, the board may be broken. Contact your Yaskawa representative. p. 61
Before you service the product, read the safety instructions in the manual p. 2.
If 4265 is still not resolved
- If your copy of the manual is damaged or lost, contact a YASKAWA representative to order a new copy. p. 2 “If your copy of the manual is damaged or lost, contact a YASKAWA representative to order a new copy.”
This page summarises what the manufacturer’s manual says about 4265; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.
