TECO A510 Error SE02: Multi‑function digital input terminal error

TECO A510 inverter · taken from the manufacturer’s manual, pages cited

Error codeSE02

SE02 on the TECO A510 is listed in the manual as: Multi‑function digital input terminal error. The manual's first action is: “Check parameter settings.”

Model
TECO A510
Display shows
Multi‑function digital input terminal error (SE02)
Type
Error code
Source
Manual p. 255

What SE02 means

Multi‑function digital input terminal error p. 255

Common causes

  • Multi‑function digital terminal error (03‑00 to 03‑07), as described below: p. 255
  • Up/down commands are not set simultaneously (they must be used together). p. 255
  • Up/down commands (08 and 09) and ACC/DEC command (11) are set at the same time. p. 255
  • Speed search 1 (19, maximum frequency) and speed search 2 (34, from set frequency) are set simultaneously. p. 255

What to do

  1. Check parameter settings. p. 255

Before you service the product, read the safety instructions in the manual p. 252.

If SE02 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TECO service.

This page summarises what the manufacturer’s manual says about SE02; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with TECO. Found a mistake? Report an error.