The axis reached the zero mark and end of traversing range without detecting the reference cam input during search. The manual's first action is: “• Check the "reference cam" input. • Repeat the search for reference.”
- Model
- Siemens SINAMICS V90, SIMOTICS S-1FL6
- Display shows
- F7460
- Type
- Fault code
- Source
- Manual p. 294
What F7460 means
During the search for reference, when the axis reached the zero mark it also reached the end of the traversing range without detecting an edge at the binector input "reference cam". p. 294
Common causes
- During the search for reference, when the axis reached the zero mark it also reached the end of the traversing range without detecting an edge at the binector input "reference cam". p. 294
What to do
- • Check the "reference cam" input. • Repeat the search for reference. p. 294
Before you service the product, read the safety instructions in the manual p. 2.
If F7460 is still not resolved
- Contact service / dealer for assistance p. 2 “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
- Contact service / dealer for assistance p. 13 “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”
This page summarises what the manufacturer’s manual says about F7460; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.