Siemens SINAMICS V90, SIMOTICS S-1FL6 Error F7447: Load gear: Position tracking, maximum actual value exceeded

Industrial motor drive · taken from the manufacturer’s manual, pages cited

Fault codeF7447

Position tracking of load gear exceeded maximum absolute position actual value within 32-bit representation limits. The manual's first action is: “Reduce the multi-turn resolution (p29244).”

Model
Siemens SINAMICS V90, SIMOTICS S-1FL6
Display shows
Load gear: Position tracking, maximum actual value exceeded (F7447)
Type
Fault code
Source
Manual p. 292

What F7447 means

Load gear: Position tracking, maximum actual value exceeded p. 292

Common causes

  • When the position tracking of the load gear is configured, the drive/encoder (motor encoder) identifies a maximum possible absolute position actual that can no longer be represented within 32 bits. Maximum value: encoder resolution (2^20 or 2^21) * p29244 p. 292

What to do

  1. Reduce the multi-turn resolution (p29244). p. 292

Before you service the product, read the safety instructions in the manual p. 2.

If F7447 is still not resolved

  • Contact service / dealer for assistance p. 2
    “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
  • Contact service / dealer for assistance p. 13
    “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”

This page summarises what the manufacturer’s manual says about F7447; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.