Fault codeF30002
The DC link voltage has exceeded its limit due to excessive motor regeneration or too-high input voltage. The manual's first action is: “Increase the ramp-down time.”
- Model
- Siemens SINAMICS V90, SIMOTICS S-1FL6
- Display shows
- DC link voltage, overvoltage (F30002)
- Type
- Fault code
- Source
- Manual p. 299
What F30002 means
DC link voltage, overvoltage p. 299
Common causes
- The power unit has detected overvoltage in the DC link. p. 299
- Motor regenerates too much energy. p. 299
- Device connection voltage too high. p. 299
- Line phase interrupted. p. 299
- Check the device supply voltage. p. 299
What to do
- Increase the ramp-down time. p. 299
- Activate the DC link voltage controller. p. 299
- Use a braking resistor. p. 299
- Increase the current limit of the infeed or use a larger module. p. 299
- Check the line supply phases. p. 299
Before you service the product, read the safety instructions in the manual p. 2.
If F30002 is still not resolved
- Contact service / dealer for assistance p. 2 “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
- Contact service / dealer for assistance p. 13 “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”
This page summarises what the manufacturer’s manual says about F30002; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.