The Inverter Overtemperature fault occurs when there is insufficient cooling airflow or the ambient temperature is too high. The manual's first action is: “Check the following: 1. The inverter’s cooling fan must operate normally during operation. 2. The modulation pulse frequency must be set to its default value. 3. Ambient temperature may exceed the inverter’s allowable limits. P0949 = 1: Rectifier overtemperature; P0949 = 2: Operating environment overtemperature; P0949 = 3: Electronic control cabinet overtemperature.”
- Model
- Siemens MICROMASTER 440
- Display shows
- Inverter Overtemperature (F0004)
- Type
- Fault code
- Source
- Manual p. 96
What F0004 means
Inverter Overtemperature p. 96
Common causes
What to do
- Check the following: 1. The inverter’s cooling fan must operate normally during operation. 2. The modulation pulse frequency must be set to its default value. 3. Ambient temperature may exceed the inverter’s allowable limits. P0949 = 1: Rectifier overtemperature; P0949 = 2: Operating environment overtemperature; P0949 = 3: Electronic control cabinet overtemperature. p. 96
Before you service the product, read the safety instructions in the manual p. 7.
If F0004 is still not resolved
This page summarises what the manufacturer’s manual says about F0004; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.