Power Component Fault means the DC circuit overcurrent, brake chopper short circuit, ground fault, or I/O boa. The manual's first action is: “Check the I/O board. It must be fully inserted. Off2”
- Model
- Siemens MICROMASTER 430
- Display shows
- Power Component Fault (F0022)
- Type
- Fault code
- Source
- Manual p. 85
What F0022 means
Power Component Fault p. 85
Common causes
- This hardware fault is triggered in the following situations (P0947 = 22 and P0949 = 1): (1) DC circuit overcurrent = IGBT short circuit; (2) Brake chopper short circuit; (3) Ground fault; (4) I/O board not properly inserted. Form factor A to C (1), (2), (3), (4); Form factor D to E (1), (2), (4); Form factor F (2), (4). Because all these faults are indicated by a single power‑component fault signal, it is not possible to determine which specific component has failed. For form factors FX and GX: when r0947 = 22 and fault value r0949 = 12, 13, or 14 (depending on UCE), a UCE fault is detected. p. 85
What to do
- Check the I/O board. It must be fully inserted. Off2 p. 85
Before you service the product, read the safety instructions in the manual p. 7.
If F0022 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about F0022; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.