Siemens MICROMASTER 430 Error F0003: Undervoltage

Siemens MICROMASTER 430 · taken from the manufacturer’s manual, pages cited

Error codeF0003

Undervoltage means the power supply failure or impact load exceeds the specified limit. The manual's first action is: “Check the following: 1. Supply voltage (P0210) must be within the range specified on the inverter nameplate.”

Model
Siemens MICROMASTER 430
Display shows
Undervoltage (F0003)
Type
Error code
Source
Manual p. 84

What F0003 means

Undervoltage p. 84

Common causes

  • Power supply failure. p. 84
  • Impact load exceeds the specified limit. p. 84

What to do

  1. Check the following: 1. Supply voltage (P0210) must be within the range specified on the inverter nameplate. p. 84
  2. 2. Check whether the supply experiences short-term power loss or transient voltage drops. p. 84
  3. 3. Enable dynamic buffering (P1240 = 2). p. 84

Before you service the product, read the safety instructions in the manual p. 7.

If F0003 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.

This page summarises what the manufacturer’s manual says about F0003; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.