A0501 indicates Current limiting when motor power does not match inverter power, motor connection wiring is too long, or there is a ground fault. The manual's first action is: “Check the following: 1. Motor power (P0307) must correspond to the inverter power (P0206).”
- Model
- Siemens MICROMASTER 430
- Display shows
- Current limiting (A0501)
- Type
- Fault code
- Source
- Manual p. 88
What A0501 means
Current limiting p. 88
Common causes
- Motor power does not match inverter power p. 88
- Motor connection wiring is too long p. 88
- Ground fault p. 88
What to do
- Check the following: 1. Motor power (P0307) must correspond to the inverter power (P0206). p. 88
Before you service the product, read the safety instructions in the manual p. 7.
If A0501 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about A0501; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.