F0090 indicates an Encoder feedback signal lost due to loss of signal from the encoder. The manual's first action is: “1. Check the encoder mounting and fixation; set P0400 = 0 and select the SLVC control mode (P1300 = 20 or 22).”
- Model
- Siemens MICROMASTER 430
- Display shows
- Encoder feedback signal lost (F0090)
- Type
- Fault code
- Source
- Manual p. 87
What F0090 means
Encoder feedback signal lost p. 87
Common causes
- Loss of signal from the encoder p. 87
What to do
- 1. Check the encoder mounting and fixation; set P0400 = 0 and select the SLVC control mode (P1300 = 20 or 22). p. 87
- 2. If an encoder is installed, verify that the encoder type is correct (check the encoder setting value in P0400). p. 87
- 3. Inspect the wiring between the encoder and the inverter. p. 87
- 4. Ensure the encoder is fault‑free (set P1300 = 0, run at a constant speed, and check the encoder feedback signal in r0061). p. 87
- 5. Increase the encoder‑signal‑loss threshold value (r0061). p. 87
Before you service the product, read the safety instructions in the manual p. 7.
If F0090 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about F0090; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.