Fault codeF0011
Motor Over-temperature î² indicates the motor has exceeded its thermal limit. The manual's first action is: “1. Check motor data”
- Model
- Siemens MICROMASTER 420
- Display shows
- Motor Over-temperature î² (F0011)
- Type
- Fault code
- Source
- Manual p. 70
What F0011 means
Motor Over-temperature î² p. 70
Common causes
Safety warnings — read before you start
- DANGERDANGER. indicates an immiently hazardous situation which, if not avoided, will result in death or serious injury. p. 6
What to do
- 1. Check motor data p. 70
- 2. Check loading on motor p. 70
- 3. Boost settings too high (P1310,P1311, P1312) p. 70
- 4. Check parameter for motor thermal time constant p. 70
- 5. Check parameter for motor î² warning level p. 70
If F0011 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about F0011; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.