Fault codeF0001
F0001 indicates an overcurrent condition due to mismatched motor and inverter power or a short circuit. The manual's first action is: “Check the following: 1. Motor power (P0307) must correspond to inverter power (P0206)”
- Model
- Siemens MICROMASTER 420
- Display shows
- Overcurrent (F0001)
- Type
- Fault code
- Source
- Manual p. 70
What F0001 means
Overcurrent p. 70
Common causes
- Motor power does not correspond to the inverter power p. 70
- Motor lead short circuit p. 70
- Earth fault p. 70
Safety warnings — read before you start
- DANGERDANGER. indicates an immiently hazardous situation which, if not avoided, will result in death or serious injury. p. 6
- WARNINGWARNING. indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. p. 6
- CAUTIONCAUTION. used with the safety alert symbol indicates a potentially hazardous situationwhich, i f not avoided, may result in minor or moderate injury. p. 6
What to do
- Check the following: 1. Motor power (P0307) must correspond to inverter power (P0206) p. 70
If F0001 is still not resolved
- Contact your service dealer for assistance. p. 70 “Check the following: 1. Motor power (P0307) must correspond to inverter power (P0206)”
This page summarises what the manufacturer’s manual says about F0001; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.