Fault codeF0003

F0003 indicates the inverter detected an undervoltage condition. The manual's first action is: “Check the following: 1. Supply voltage (P0210) must lie within limits indicated on rating plate”

Model
Siemens MICROMASTER 420
Display shows
Undervoltage (F0003)
Type
Fault code
Source
Manual p. 70

What F0003 means

Undervoltage p. 70

Common causes

  • Main supply failed p. 70
  • Shock load outside specified limits p. 70

Safety warnings — read before you start

  • DANGERDANGER. indicates an immiently hazardous situation which, if not avoided, will result in death or serious injury. p. 6
  • WARNINGWARNING. indicates a potentially hazardous situation which, if not avoided, could result indeath or serious injury. p. 6
  • CAUTIONCAUTION. used with the safety alert symbol indicates a potentially hazardous situationwhich, i f not avoided, may result in minor or moderate injury. p. 6

What to do

  1. Check the following: 1. Supply voltage (P0210) must lie within limits indicated on rating plate p. 70
  2. 2. Supply must not be susceptible to temporary failures or voltage reductions p. 70

If F0003 is still not resolved

  • Contact your service dealer for assistance. p. 70
    “Check the following: 1. Supply voltage (P0210) must lie within limits indicated on rating plate”

This page summarises what the manufacturer’s manual says about F0003; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.