Error codeF30809
The power unit detected an invalid switching information end ID in the setpoint telegram for a 3P gating unit. The manual's first action is: “- carry out a POWER ON (switch-off/switch-on) for all components.”
- Model
- Siemens G120C
- Display shows
- Power unit: Switching information not valid (F30809)
- Type
- Error code
- Source
- Manual p. 749
What F30809 means
Power unit: Switching information not valid p. 749
Common causes
- For 3P gating unit, the following applies: The last switching status word in the setpoint telegram is identified by the end ID. Such an end ID was not found. p. 749
What to do
- - carry out a POWER ON (switch-off/switch-on) for all components. p. 749
- - upgrade firmware to later version. p. 749
- - contact Technical Support. p. 749
Before you service the product, read the safety instructions in the manual p. 4.
If F30809 is still not resolved
This page summarises what the manufacturer’s manual says about F30809; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.