Siemens G120C Error F30600: SI P2: STOP A initiated

Siemens G120C drive · taken from the manufacturer’s manual, pages cited

Fault codeF30600

Processor 2 of the drive’s Safety Integrated function has initiated a STOP A because it detected an error in its safety signal path or failed to respond to fault F30611. The manual's first action is: “0: Stop request from processor 1.”

Model
Siemens G120C
Display shows
SI P2: STOP A initiated (F30600)
Type
Fault code
Source
Manual p. 743

What F30600 means

SI P2: STOP A initiated p. 743

Common causes

  • The drive-integrated "Safety Integrated" function on processor 2 has detected an error and initiated a STOP A. p. 743
  • - forced checking procedure (test stop) of the safety switch-off signal path on processor 2 unsuccessful. p. 743
  • - subsequent response to fault F30611 (defect in a monitoring channel). p. 743
  • Fault value (r0949, interpret decimal): p. 743
  • 1005: Pulses suppressed although STO not selected and there is no internal STOP A present. p. 743
  • 1010: Pulses enabled although STO is selected or an internal STOP A is present. p. 743
  • 1011: Internal fault for the pulse enable in the Power Module. p. 743
  • Remedy: p. 743
  • For fault value = 9999: p. 743
  • Note: p. 743
  • STO: Safe Torque Off p. 743

What to do

  1. 0: Stop request from processor 1. p. 743
  2. 9999: Subsequent response to fault F30611. p. 743
  3. - select Safe Torque Off and de-select again. p. 743
  4. - carry out a POWER ON (switch-off/switch-on) for all components. p. 743
  5. - replace Power Module involved. p. 743
  6. - carry out diagnostics for fault F30611. p. 743
  7. PM: Power Module p. 743

Before you service the product, read the safety instructions in the manual p. 4.

If F30600 is still not resolved

  • contact service / dealer p. 4
    “Warning concept This Manual contains information which you must observe to ensure your own personal safety as well as to avoid material damage.”
  • contact service / dealer p. 12
    “WARNING Danger to life if the safety instructions and residual risks are not observed”

This page summarises what the manufacturer’s manual says about F30600; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.