Fault codeF00452
Belt Failure is triggered when load conditions indicate belt failure or mechanical fault, typically during low torque/speed events. The manual's first action is: “Quit fault eg. via D12”
- Model
- Siemens CU240S
- Display shows
- Belt Failure (F00452)
- Type
- Fault code
- Source
- Manual p. 390
What F00452 means
Belt Failure p. 390
Common causes
- OFF 2 (OFF 3) p. 390
- Load conditions on motor indicate belt failure or mechanical fault. p. 390
- r0948 = 0: trip low torque/speed p. 390
- r0948 = 1: trip high torque/speed p. 390
What to do
- Quit fault eg. via D12 p. 390
If F00452 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about F00452; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.