The Siemens CU240S lost the motor temperature signal, likely due to an open or short circuit in the sensor, and switched to thermal model monitoring. The manual's first action is: “Check the following: • the connection of the motor temperature sensor to the control unit • the setting of p0601”
- Model
- Siemens CU240S
- Display shows
- Motor temperature signal lost (F00015)
- Type
- Fault code
- Source
- Manual p. 381
What F00015 means
Motor temperature signal lost p. 381
Common causes
- Open or short circuit of motor temperature sensor. If signal loss is detected, temperature monitoring switches over to monitoring with the motor thermal model. p. 381
What to do
- Check the following: • the connection of the motor temperature sensor to the control unit • the setting of p0601 p. 381
If F00015 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about F00015; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.