SEW MOVITRAC-07 Error 07: DC-link over-voltage

Frequency inverter · taken from the manufacturer’s manual, pages cited

Fault code07

Code 07 indicates DC-link over-voltage caused by DC link voltage too high or ground fault. The manual's first action is: “Extend deceleration ramps”

Model
SEW MOVITRAC-07
Display shows
DC-link over-voltage (07)
Type
Fault code
Source
Manual p. 45

What 07 means

DC-link over-voltage p. 45

Common causes

  • DC link voltage too high p. 45
  • Ground fault p. 45

What to do

  1. Extend deceleration ramps p. 45
  2. Check connecting harness for braking resistor p. 45
  3. Check technical data of braking resistor p. 45
  4. Rectify the ground fault p. 45

If 07 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact SEW service.