Fault code01
Code 01 indicates an over-current condition caused by a short circuit on output, output switching, or motor too large. The manual's first action is: “Rectify the short circuit”
- Model
- SEW MOVITRAC-07
- Display shows
- Over-current (01)
- Type
- Fault code
- Source
- Manual p. 45
What 01 means
Over-current p. 45
Common causes
- Short circuit on output p. 45
- Output switching p. 45
- Motor too large p. 45
- Defective output stage p. 45
- Ramp limit (P138) switched off p. 45
What to do
- Rectify the short circuit p. 45
- Only switch when output stage inhibited p. 45
- Connect a smaller motor p. 45
- Call SEW Service for advice if the fault still cannot be reset p. 45
- Ramp limit (P138 = YES) p. 45
If 01 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact SEW service.
This page summarises what the manufacturer’s manual says about 01; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with SEW. Found a mistake? Report an error.