Fault code25
Code 25 indicates EEPROM fault when accessing EEPROM. The manual's first action is: “Call up default setting, perform reset and set parameters again. Contact SEW Service for advice if this reoccurs.”
- Model
- SEW MOVITRAC-07
- Display shows
- EEPROM (25)
- Type
- Fault code
- Source
- Manual p. 46
What 25 means
EEPROM p. 46
Common causes
- Fault when accessing EEPROM p. 46
What to do
- Call up default setting, perform reset and set parameters again. Contact SEW Service for advice if this reoccurs. p. 46
If 25 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact SEW service.