The [Encoder] code indicates an encoder feedback fault or incorrect mechanical and electrical operation of the encoder. The manual's first action is: “Check the [Pulse Count] (PGI) and [Encoder Type] (EnS) on page 73.”
- Model
- Schneider Electric ATV61
- Display shows
- [Encoder] (EnF)
- Type
- Fault code
- Source
- Manual p. 239
What EnF means
[Encoder] p. 239
Common causes
- Encoder feedback fault. p. 239
- Check the mechanical and electrical operation of the encoder, and verify that its power supply and wiring are correct. p. 239
What to do
- Check the [Pulse Count] (PGI) and [Encoder Type] (EnS) on page 73. p. 239
- If necessary, reverse the motor (using the [Change Output Phase Sequence] (PHr) parameter on page 66) or the rotation direction of the encoder signal. p. 239
Before you service the product, read the safety instructions in the manual p. 54.
If EnF is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.
This page summarises what the manufacturer’s manual says about EnF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.