Schneider Electric ATV212 Error N0FF: [Undervoltage fault]

Schneider Electric ATV212 · taken from the manufacturer’s manual, pages cited

Fault codeN0FF

The input voltage is too low. The manual's first action is: “Measure the main circuit supply voltage. If the voltage is normal, the inverter requires repair.”

Model
Schneider Electric ATV212
Display shows
[Undervoltage fault] (N0FF)
Type
Fault code
Source
Manual p. 156

What N0FF means

[Undervoltage fault] p. 156

Common causes

  • The input voltage is too low. p. 156

What to do

  1. Measure the main circuit supply voltage. If the voltage is normal, the inverter requires repair. p. 156

Before you service the product, read the safety instructions in the manual p. 5.

If N0FF is still not resolved

  • 与当地的 Schneider Electric 代表联系 p. 7
    “如果直流总线电容未完全放电,请与当地的 Schneider Electric 代表联系”

This page summarises what the manufacturer’s manual says about N0FF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.