Schneider Electric ATV212 Error P: [DC bus alarm]

Schneider Electric ATV212 · taken from the manufacturer’s manual, pages cited

Alarm codeP

The P code indicates a DC bus alarm when the inverter is approaching an over-voltage fault due to excessively high supply voltage, regenerative braking, or a combination of both. The manual lists no action for this code.

Model
Schneider Electric ATV212
Display shows
[DC bus alarm] (P)
Type
Alarm code
Source
Manual p. 157

What P means

[DC bus alarm] p. 157

Common causes

  • Because of excessively high supply voltage, regenerative braking, or a combination of both, the inverter is approaching an over‑voltage fault. See parameters F305 (page 130) and F626 (page 130) for more information. p. 157

If P is still not resolved

  • 与当地的 Schneider Electric 代表联系 p. 7
    “如果直流总线电容未完全放电,请与当地的 Schneider Electric 代表联系”

This page summarises what the manufacturer’s manual says about P; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.