Fault codeOPF1
OPF1 indicates loss of one phase at drive output. The manual's first action is: “Check the connections from the drive to the motor.”
- Model
- Schneider Electric Altivar 61
- Display shows
- [1 motor phase loss] (OPF1)
- Type
- Fault code
- Source
- Manual p. 55
What OPF1 means
[1 motor phase loss] p. 55
Common causes
- Loss of one phase at drive output p. 55
What to do
- Check the connections from the drive to the motor. p. 55
Before you service the product, read the safety instructions in the manual p. 33.
If OPF1 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.
This page summarises what the manufacturer’s manual says about OPF1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.