Fault codeGTF1
GTF1 indicates overheating of the PTC1 probes detected. The manual's first action is: “Check the motor load and motor size.”
- Model
- Schneider Electric Altivar 61
- Display shows
- [PTC1 overheat] (GTF1)
- Type
- Fault code
- Source
- Manual p. 56
What GTF1 means
[PTC1 overheat] p. 56
Common causes
- Overheating of the PTC1 probes detected p. 56
What to do
- Check the motor load and motor size. p. 56
- Check the motor ventilation. p. 56
- Wait for the motor to cool before restarting. p. 56
- Check the type and state of the PTC probes. p. 56
Before you service the product, read the safety instructions in the manual p. 33.
If GTF1 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.
This page summarises what the manufacturer’s manual says about GTF1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.