The system has exceeded its maximum storage limit of 500 programs. The manual's first action is: “Delete unnecessary program.”
Subprogram is called too many times. The manual's first action is: “Subprogram call times: 1-999. Modify the program.”
The program contains a non-integral or negative value for parameter P. The manual's first action is: “Check the program. See the programming manual for details.”
Group G00 and group G01 cannot both be active simultaneously in the program. The manual's first action is: “Modify the program, and delete redundant G code.”
The value of the address exceeds the range. The manual's first action is: “There are specified ranges for addresses. Modify the program. See programming manual for details.”
An alarm occurs when more than two G codes in the same group are used in one block. The manual's first action is: “Modify the program. See programming manual for details.”
The sequence number for address transfer is out of range or not found. The manual's first action is: “Modify the program, and use the correct sequence number.”
An illegal variable number has been specified in the program. The manual's first action is: “Modify the program, and specify the correct variable number.”
In G65 block, undefined H code is specified. The manual's first action is: “Check program, and specify the correct H code.”
The program name already exists when copied and renamed. The manual's first action is: “Select a new program name, and perform again.”
The drive, spindle etc. are changing. The manual's first action is: “Restart the system again.”
The system detects abnormal absolute data and requires tool reset. The manual's first action is: “Read initialized disk again. If they still exist after power on, please change the main board.”
The system detects abnormal tool length compensation data. The manual's first action is: “Read initialized disk again. If they still exist after power on, please change the main board.”
CNC abnormality is detected, it needs to check parameter again. The manual's first action is: “Read initialized disk again. If they still exist after power on, please change the main board.”
Memory data, tool compensation and coordinate have been initialized. The manual's first action is: “Read initialized disk again. If they still exist after power on, please change the main board.”