Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Suspected wrong connection during power-up. Remote Tsen+ connected to BAT- The manual's first action is: “This error will auto-reset after proper connection.”
Suspected wrong connection during power-up. Remote Tsen+ connected to BAT+ The manual's first action is: “This error will auto-reset after proper connection.”
Battery voltage is too high (>76.8V) The manual lists no action for this code.
Battery temperature exceeds 50°C. The manual's first action is: “If error persists and charging does not resume, replace sensor, and power-up by entering and leaving the setup menu.”
All 20 error codes of the Victron Energy MPPT 150/70 CAN-bus MPPT 150/70 CAN-bus with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
259 on the GSK GSK980TB3 is listed in the manual as: Timer has faults.. The manual's first action is: “Please contact the manufacturer for help.”
IO port setting is wrong. The manual's first action is: “Please contact the manufacturer for help.”
Safety door is open during automatic operation. The manual's first action is: “Change alarm level parameter NO.16 Bit6 or parameter NO.16 Bit5 to 0: Shield safety door function.”
The system is not ready because the emergency stop is active. The manual's first action is: “Check whether the emergency stop button is pressed down, or change parameter NO.14 Bit3 to 1: Shield emergency stop.”
The system detects low pressure in the circuit. The manual's first action is: “Check whether the pressure circuit is correct, or change alarm level parameter NO.16 Bit3 or NO.16 Bit4 to 0: Shield pressure detection.”
External alarm 2 is active. The manual's first action is: “Check whether the external alarm circuit is correct, or change alarm level parameter NO.12 Bit3 or NO.12 Bit7 to 0: Shield pressure detection.”
External alarm 1 is active. The manual's first action is: “Check whether the external alarm circuit is correct, or change alarm.”
Tailstock advance/retract can not be performed in Auto mode or after the spindle is started. The manual's first action is: “Execute M05 and then perform M10/M11.”
Z-axis has moved beyond its allowed travel range. The manual lists no action for this code.
X-axis overtravel alarm indicates the X-axis has moved beyond its safe travel limits. The manual lists no action for this code.