P,U and X in the pause command can not be specified at the same time. The manual's first action is: “Delete unnecessary address characters.”
Pno and Qno values assigned by G70, G71, G72, or G73 exceed the range or are non-integral. The manual's first action is: “Check the program. See the programming manual for details.”
The sentence for calling subprogram or returning subprogram is in illegal block (G90-G94, G70~G76). The manual's first action is: “Check the program. See the programming manual for details.”
The system has exceeded its maximum storage limit of 500 programs. The manual's first action is: “Delete unnecessary program.”
Subprogram is called too many times. The manual's first action is: “Subprogram call times: 1-999. Modify the program.”
The program contains a non-integral or negative value for parameter P. The manual's first action is: “Check the program. See the programming manual for details.”
Group G00 and group G01 cannot both be active simultaneously in the program. The manual's first action is: “Modify the program, and delete redundant G code.”
The value of the address exceeds the range. The manual's first action is: “There are specified ranges for addresses. Modify the program. See programming manual for details.”
An alarm occurs when more than two G codes in the same group are used in one block. The manual's first action is: “Modify the program. See programming manual for details.”
The sequence number for address transfer is out of range or not found. The manual's first action is: “Modify the program, and use the correct sequence number.”
An illegal variable number has been specified in the program. The manual's first action is: “Modify the program, and specify the correct variable number.”
In G65 block, undefined H code is specified. The manual's first action is: “Check program, and specify the correct H code.”
The program name already exists when copied and renamed. The manual's first action is: “Select a new program name, and perform again.”
The drive, spindle etc. are changing. The manual's first action is: “Restart the system again.”
The system detects abnormal absolute data and requires tool reset. The manual's first action is: “Read initialized disk again. If they still exist after power on, please change the main board.”