The system did not receive a signal that the chuck is in position within the allowed time. The manual's first action is: “Check whether the wire of external alarm is correct. Adjust parameter P91 arrival time or modif…
M45~M49 commands are executed while corresponding in-position input signal is not received. The manual's first action is: “In-position input signal is necessary for executing M45-M49. Check whether the circuit is corr…
Tool change is not ready because tool number does not match current tool number. The manual's first action is: “Press reset key to cancel the alarm or adjust position of signal sending disk, or according to the state …
The system has not received the tool post’s reverse locking signal within the tool post reverse locking time. The manual's first action is: “According to TCP input state of parameter NO.1 Bit7, check whether the setti…
Alarm 185 occurs when tool changing time exceeds set limit and tool position signal is not received. The manual's first action is: “According to input state of NO.2 T01-T08, check whether the setting of NO.9 Bit1 is c…
T code is wrong. Illegal T code is edited in the program. The manual's first action is: “Corresponding parameter is not set. See parameter list of the manual.”
S code is wrong. Illegal S code is edited in the program. The manual's first action is: “Corresponding parameter is not set. See parameter list of the manual.”
M code is wrong. Illegal M code is edited in the program. The manual's first action is: “Corresponding parameter is not set. See parameter list of the manual.”
M41-M44 cannot be used when spindle is in gear control or automatic gearing is inactive. The manual's first action is: “Requirements for using M41-M44: frequency conversion and spindle automatic gearing is active. Cha…
The spindle enable signal is not being received. The manual's first action is: “Check SPEN input state of parameter NO.3, and check whether circuit of the external spindle enable signal is normal, or change parameter …
Incorrect password entered before modifying parameters or screw pitch compensation data. The manual's first action is: “It is necessary to input password before modifying parameter and screw pitch. See programming man…
Q and R in macro program are specified incorrectly. The manual's first action is: “Check the program. See the programming manual for details.”
P,U and X in the pause command can not be specified at the same time. The manual's first action is: “Delete unnecessary address characters.”
Pno and Qno values assigned by G70, G71, G72, or G73 exceed the range or are non-integral. The manual's first action is: “Check the program. See the programming manual for details.”
The sentence for calling subprogram or returning subprogram is in illegal block (G90-G94, G70~G76). The manual's first action is: “Check the program. See the programming manual for details.”