Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
The registration sensor is still OFF after 150 mm of recording paper has been fed. The manual lists no action for this code.
The cam sensor cannot go OFF after coming ON even if the switching cam turns reverse. The manual lists no action for this code.
The cam sensor cannot detect the home position of the switching cam even after one full turn of the cam. The manual lists no action for this code.
The cam sensor detected the switching cam at an unexpected timing while in the home position. The manual lists no action for this code.
The cam sensor sticks to ON. The manual lists no action for this code.
The cam sensor sticks to OFF. The manual lists no action for this code.
Memory management error indicates a defective main PCB. The manual's first action is: “Replace the main PCB.”
Internal software error. The manual's first action is: “Replace the main PCB.”
Internal software error. The manual's first action is: “Replace the main PCB.”
Document removed at phase B. The manual's first action is: “Correct the surrounding parts on which the actuator caught.”
Data scanning error during transmission. The manual's first action is: “Replace the CIS unit.”
Write error in EEPROM. The manual's first action is: “Replace the main PCB.”
The fax machine detected a missing serial number or customized code. The manual's first action is: “Input the serial number (function code 80) or customized code (function code 74)”
Modem error indicates a defective main PCB. The manual's first action is: “Replace the main PCB.”
The LED array has abnormal light intensity. The manual's first action is: “Replace the CIS unit.”