Error code OL1 indicates motor overload caused by incorrect setting of motor rated current, motor protection action time set too short, or acceleration/deceleration time too short. The manual's first action is: “→ Verify the motor nameplate and set the rated current in n7.00”
- Model
- Omron SYSDRIVE 3G3MZ
- Display shows
- Motor overload (OL1) (OL1)
- Type
- Fault code
- Source
- Manual p. 167
What OL1 means
Motor overload (OL1) p. 167
Common causes
- Incorrect setting of motor rated current (n7.00) p. 167
- Motor protection action time (n6.07) set too short p. 167
- Acceleration/deceleration time too short p. 167
- Maximum voltage/frequency (n1.01) set too low p. 167
- Abnormal V/f setting p. 167
- Driving multiple motors with one inverter p. 167
- Excessive load p. 167
- Increase motor capacity p. 167
What to do
- → Verify the motor nameplate and set the rated current in n7.00 p. 167
- → Set n6.07 to the factory default of “60” p. 167
- → Extend acceleration/deceleration time p. 167
- → Verify the motor nameplate and set the rated frequency in n1.01 p. 167
- → Return the V/f mode setting to its initial value. p. 167
- → Disable motor overload detection. Set thermal protection to inactive by setting n6.06 = “2” in each motor. p. 167
- → Reduce the load p. 167
Before you service the product, read the safety instructions in the manual p. 170.
If OL1 is still not resolved
- contact service or dealer p. 170 “警告发生时,请根据下表来检测原因,采取妥当的措施”
This page summarises what the manufacturer’s manual says about OL1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.