Omron SYSDRIVE 3G3MZ Error eF2.0: EEPROM (PB) read error (CF2.0)

Variable frequency drive · taken from the manufacturer’s manual, pages cited

Error codeeF2.0

Error code eF2.0 indicates EEPROM (PB) read error caused by internal EEPROM malfunction in the inverter. The manual's first action is: “→ Internal circuit fault → Perform a reset, initialize parameters (n0.02 = “0” or “10”), then power OFF/ON → If the error persists after power cycling, replace the inverter”

Model
Omron SYSDRIVE 3G3MZ
Display shows
EEPROM (PB) read error (CF2.0) (eF2.0)
Type
Error code
Source
Manual p. 169

What eF2.0 means

EEPROM (PB) read error (CF2.0) p. 169

Common causes

  • Internal EEPROM malfunction in the inverter p. 169

What to do

  1. → Internal circuit fault → Perform a reset, initialize parameters (n0.02 = “0” or “10”), then power OFF/ON → If the error persists after power cycling, replace the inverter p. 169

Before you service the product, read the safety instructions in the manual p. 170.

If eF2.0 is still not resolved

  • contact service or dealer p. 170
    “警告发生时,请根据下表来检测原因,采取妥当的措施”

This page summarises what the manufacturer’s manual says about eF2.0; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.