Omron SYSDRIVE 3G3MZ Error OH1: Heatsink overtemperature (OH1)

Variable frequency drive · taken from the manufacturer’s manual, pages cited

Error codeOH1

Error code OH1 indicates heatsink overtemperature caused by cooling fan stopped or cooling fan action selection is inaccurate. The manual's first action is: “→ Replace the cooling fan (applicable only to inverters equipped with a fan)”

Model
Omron SYSDRIVE 3G3MZ
Display shows
Heatsink overtemperature (OH1) (OH1)
Type
Error code
Source
Manual p. 167

What OH1 means

Heatsink overtemperature (OH1) p. 167

Common causes

  • Cooling fan stopped (cooling fan has reached end of life/failure) p. 167
  • Cooling fan action selection is inaccurate p. 167

What to do

  1. → Replace the cooling fan (applicable only to inverters equipped with a fan) p. 167
  2. → Set the cooling fan action selection (n308) to “0” (applicable only to inverters equipped with a fan) p. 167

Before you service the product, read the safety instructions in the manual p. 170.

If OH1 is still not resolved

  • contact service or dealer p. 170
    “警告发生时,请根据下表来检测原因,采取妥当的措施”

This page summarises what the manufacturer’s manual says about OH1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.