Error codebb
Error code bb indicates external base lock caused by external base-lock command was entered or sequence abnormal. The manual's first action is: “→ Eliminate the cause of the external base‑lock command input”
- Model
- Omron SYSDRIVE 3G3MZ
- Display shows
- External base lock (BB) (bb)
- Type
- Error code
- Source
- Manual p. 169
What bb means
External base lock (BB) p. 169
Common causes
- External base‑lock command was entered (any of the multifunction input selections n4.03–n4.05 set to “9” for external base lock, and that input was activated) p. 169
- Sequence abnormal p. 169
What to do
- → Eliminate the cause of the external base‑lock command input p. 169
- → Correct the input sequence for the external base‑lock command (input timing, distinction between a‑contact and b‑contact, etc.) p. 169
Before you service the product, read the safety instructions in the manual p. 170.
If bb is still not resolved
- contact service or dealer p. 170 “警告发生时,请根据下表来检测原因,采取妥当的措施”
This page summarises what the manufacturer’s manual says about bb; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.