Omron SYSDRIVE 3G3MZ Error bb: External base lock (BB)

Variable frequency drive · taken from the manufacturer’s manual, pages cited

Error codebb

Error code bb indicates external base lock caused by external base-lock command was entered or sequence abnormal. The manual's first action is: “→ Eliminate the cause of the external base‑lock command input”

Model
Omron SYSDRIVE 3G3MZ
Display shows
External base lock (BB) (bb)
Type
Error code
Source
Manual p. 169

What bb means

External base lock (BB) p. 169

Common causes

  • External base‑lock command was entered (any of the multifunction input selections n4.03–n4.05 set to “9” for external base lock, and that input was activated) p. 169
  • Sequence abnormal p. 169

What to do

  1. → Eliminate the cause of the external base‑lock command input p. 169
  2. → Correct the input sequence for the external base‑lock command (input timing, distinction between a‑contact and b‑contact, etc.) p. 169

Before you service the product, read the safety instructions in the manual p. 170.

If bb is still not resolved

  • contact service or dealer p. 170
    “警告发生时,请根据下表来检测原因,采取妥当的措施”