Omron OMNUC G Error 12: Overvoltage

Omron OMNUC G · taken from the manufacturer’s manual, pages cited

Error code12

This code indicates overvoltage. The manual's first action is: “Possible”

Model
Omron OMNUC G
Display shows
Overvoltage (12)
Type
Error code
Source
Manual p. 343

What 12 means

Overvoltage p. 402

Common causes

  • Main circuit DC voltage is abnormally high. p. 402
  • Occurs when power is applied. p. 402
  • Large load inertia. p. 402
  • Main circuit power voltage exceeds allowable range. p. 402
  • Excessive gravitational torque. p. 402

What to do

  1. Possible p. 402
  2. • Voltage exceeds the allowable range of the main circuit power supply • Adjust to within the allowable range. p. 402
  3. • Calculate regenerated energy and connect an external regeneration resistor with the required absorption capability. • Extend deceleration time. p. 402
  4. • Adjust to within the allowable range of the main circuit power voltage. p. 402
  5. • Add a balancing device to the equipment to reduce gravitational load • Decrease descent speed • Calculate regenerated energy and connect an external regeneration resistor with the required absorption capability. p. 402

Before you service the product, read the safety instructions in the manual p. 273.

If 12 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.