Error code11
This code indicates insufficient control power supply voltage. The manual's first action is: “Possible”
- Model
- Omron OMNUC G
- Display shows
- Insufficient control power supply voltage (11)
- Type
- Error code
- Source
- Manual p. 343
What 11 means
Insufficient control power supply voltage p. 402
Common causes
- During RUN command input, the main circuit DC voltage drops below the specified value. p. 402
- Occurs when the servo is ON. p. 402
- Insufficient power supply capacity. p. 402
- Phase loss. p. 402
- Main circuit power part damaged; control board abnormal. p. 402
What to do
- Possible p. 402
- • Increase power supply capacity • Change power source • Connect power supply p. 402
- • Increase power supply capacity p. 402
- • Correctly connect each phase of the power voltage (L1, L2, L3) • If single‑phase, connect correctly to L1 and L3 p. 402
- • Replace the drive p. 402
Before you service the product, read the safety instructions in the manual p. 273.
If 11 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.