Omron OMNUC G Error 11: Insufficient control power supply voltage

Omron OMNUC G · taken from the manufacturer’s manual, pages cited

Error code11

This code indicates insufficient control power supply voltage. The manual's first action is: “Possible”

Model
Omron OMNUC G
Display shows
Insufficient control power supply voltage (11)
Type
Error code
Source
Manual p. 343

What 11 means

Insufficient control power supply voltage p. 402

Common causes

  • During RUN command input, the main circuit DC voltage drops below the specified value. p. 402
  • Occurs when the servo is ON. p. 402
  • Insufficient power supply capacity. p. 402
  • Phase loss. p. 402
  • Main circuit power part damaged; control board abnormal. p. 402

What to do

  1. Possible p. 402
  2. • Increase power supply capacity • Change power source • Connect power supply p. 402
  3. • Increase power supply capacity p. 402
  4. • Correctly connect each phase of the power voltage (L1, L2, L3) • If single‑phase, connect correctly to L1 and L3 p. 402
  5. • Replace the drive p. 402

Before you service the product, read the safety instructions in the manual p. 273.

If 11 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.

This page summarises what the manufacturer’s manual says about 11; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.