Warning code90
Detector, initial communication error means initial communication with the absolute position linear scale was not possible or setting is incorrect. The manual's first action is: “PR”
- Model
- Mitsubishi Electric MDS-C1 Series
- Display shows
- Detector, initial communication error (90)
- Type
- Warning code
- Source
- Manual p. 314
What 90 means
Detector, initial communication error p. 314
Common causes
- Initial communication with the absolute position linear scale was not possible. p. 314
- The setting is incorrect. p. 314
- The setting is correct. p. 314
- The connector is disconnected (loose). p. 314
- The connector is not disconnected. p. 314
- The connection is faulty. p. 314
- The connection is normal. p. 314
- No abnormality is found in particular. p. 314
- An abnormality was found in the ambient environment. p. 314
What to do
- PR p. 314
- Correctly set SV025. p. 314
- Investigate item 2. p. 314
- Correctly install. p. 314
- Investigate item 3. p. 314
- Replace the detector cable (CN3 side). p. 314
- Investigate item 4. p. 314
- Replace the tool end detector. (With the absolute position system, the zero point must be established.) p. 314
- Take remedies according to the causes of the abnormality. Ex. High temperature: Check the cooling fan. Incomplete grounding: Additionally ground. p. 314
Before you service the product, read the safety instructions in the manual p. 4.
If 90 is still not resolved
- contact service / dealer p. 5 “Wiring, maintenance and inspection work must be done by a qualified technician.”
This page summarises what the manufacturer’s manual says about 90; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.