Error code2B
A CPU initial error occurred with the motor end detector or linear scale in the linear servo system. The manual's first action is: “PR”
- Model
- Mitsubishi Electric MDS-C1 Series
- Display shows
- Motor side detector, CPU error 1 (2B)
- Type
- Error code
- Source
- Manual p. 310
What 2B means
Motor side detector, CPU error 1 p. 310
Common causes
- A CPU initial error was detected with the motor end detector or linear scale in the linear servo system. p. 310
- Check if there is any abnormality in the detector's ambient environment. (Ex. Ambient temperature, noise, grounding) p. 310
What to do
- PR p. 310
- No abnormality is found in particular. Replace the detector. (With the absolute position system, the zero point must be established.) p. 310
Before you service the product, read the safety instructions in the manual p. 4.
If 2B is still not resolved
- contact service / dealer p. 5 “Wiring, maintenance and inspection work must be done by a qualified technician.”
This page summarises what the manufacturer’s manual says about 2B; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.