Mitsubishi Electric MDS-C1 Series Error 2B: Motor side detector, CPU error 1

AC Servo/Spindle · taken from the manufacturer’s manual, pages cited

Error code2B

A CPU initial error occurred with the motor end detector or linear scale in the linear servo system. The manual's first action is: “PR”

Model
Mitsubishi Electric MDS-C1 Series
Display shows
Motor side detector, CPU error 1 (2B)
Type
Error code
Source
Manual p. 310

What 2B means

Motor side detector, CPU error 1 p. 310

Common causes

  • A CPU initial error was detected with the motor end detector or linear scale in the linear servo system. p. 310
  • Check if there is any abnormality in the detector's ambient environment. (Ex. Ambient temperature, noise, grounding) p. 310

What to do

  1. PR p. 310
  2. No abnormality is found in particular. Replace the detector. (With the absolute position system, the zero point must be established.) p. 310

Before you service the product, read the safety instructions in the manual p. 4.

If 2B is still not resolved

  • contact service / dealer p. 5
    “Wiring, maintenance and inspection work must be done by a qualified technician.”

This page summarises what the manufacturer’s manual says about 2B; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.