Warning codeOPW0111
The manual feedrate switch is set to "0" during jog or dry run mode, or there's a short circuit in the signal wire or sequence program error. The manual's first action is: “Set the switch to a value other than "0" to release the error.”
- Model
- Mitsubishi Electric 600M Series
- Display shows
- External feedrate zero (OPW0111)
- Type
- Warning code
- Source
- Manual p. 501
What OPW0111 means
External feedrate zero p. 501
Common causes
- The MANUAL FEEDRATE switch on the machine operation panel is set to "0" when the machine is in the jog mode or automatic dry run mode. p. 501
- If the switch is set to a value other than "0", check for a short circuit in the signal wire. p. 501
- Check the sequence program. p. 501
What to do
- Set the switch to a value other than "0" to release the error. p. 501
Before you service the product, read the safety instructions in the manual p. 4.
If OPW0111 is still not resolved
This page summarises what the manufacturer’s manual says about OPW0111; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.