Mitsubishi Electric 600M Series Error AX0101: H/W stroke end axis exists

CNC milling machine · taken from the manufacturer’s manual, pages cited

Error codeAX0101

An axis has reached its physical stroke end and the limit switch is activated; manual movement is required to proceed. The manual's first action is: “The stroke end limit switch is activated (is at the stroke end), so move the machine with a manual operation.”

Model
Mitsubishi Electric 600M Series
Display shows
H/W stroke end axis exists (AX0101)
Type
Error code
Source
Manual p. 474

What AX0101 means

H/W stroke end axis exists p. 474

Common causes

  • An axis exists at its stroke end, and the stroke end function is validated (the input signal is OFF). p. 474

What to do

  1. The stroke end limit switch is activated (is at the stroke end), so move the machine with a manual operation. p. 474
  2. Check for broken wires in the stroke end signal line. p. 474
  3. Check whether the limit switch is faulty. p. 474

Before you service the product, read the safety instructions in the manual p. 4.

If AX0101 is still not resolved

  • contact service / dealer p. 5
    “Do not change the fixed cycle program without prior consent from the machine manufacturer.”
  • contact service / dealer p. 5
    “Do not turn OFF the NC a”

This page summarises what the manufacturer’s manual says about AX0101; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.