The machine moved beyond the allowable amount while powered off, causing a positional tolerance violation during restart. The manual's first action is: “The tolerable movement amount is set in "270003 Move amnt in pwr OFF" on the Absolute Position Setting screen.”
- Model
- Mitsubishi Electric 600M Series
- Display shows
- Abs posn tolerance amnt over (AX0022)
- Type
- Error code
- Source
- Manual p. 474
What AX0022 means
Abs posn tolerance amnt over p. 474
Common causes
- The machine moved over the allowable movement amount with the power OFF. p. 474
- Allowable movement amount > (absolute position when the power is turned ON - absolute position when the power is turned OFF) p. 474
What to do
- The tolerable movement amount is set in "270003 Move amnt in pwr OFF" on the Absolute Position Setting screen. p. 474
- The setting range is 0.001 to 99999.99m, but if 0 is set, the check will be invalidated. p. 474
Before you service the product, read the safety instructions in the manual p. 4.
If AX0022 is still not resolved
This page summarises what the manufacturer’s manual says about AX0022; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.